Scenario 1:
- Open the WD.
- Click "Create element with external tool" button on the toolbar.
- In the "Configure Element with External Tool" wizard go to the "Input data" page and add a row.
- Input some value to the "Display name".
- While editing the name (see "editing_name.png"), press Esc on the keyboard.
Current result: the wizard is closed, all settings are lost.
Expected result: the wizard is NOT closed, the cell is selected.
Scenario 2:
- Open the WD.
- Click "Create element with external tool" button on the toolbar.
- In the "Configure Element with External Tool" wizard go to the "Input data" page and add a row.
- Input some value to the "Display name".
- Select a cell.
- Press Esc on the keyboard.
Current result: the wizard is closed, all settings are lost.
Expected result: additional dialog is shown with title "Close the Wizard", button "Close" (default) and "Cancel", and message:Would you like to close the configuration wizard? All settings will be lost.
Notes:
- In scenario 1 other tables in the wizard (on the "Parameters" and "Output data" pages) should be treated in the same way.
- In scenario 2 the dialog with the message should appear on any page of the wizard if some data were modified only, i.e. if there were no modification, just close the wizard!
- Both element creation and editing should be tested.
- relates to
-
UGENE-6332 Improve adding of workflow elements with CMD tools
- Closed