Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: 47
-
Component/s: None
-
Labels:
-
Sprint:DEV-47-5, DEV-47-RELEASE
-
Affect Type:Userdefined
Reproducible in debug version 47.dev. In 46.0 all works fine.
Scenario:
- Open In Silico PCR element in Workflow Designer
- Melting temperature by default is Primer3 in Option Panel instead of Rough like in 46.0
- Open Melting temperature dialog, select Rough algorithm, push OK
- Dialog is closed, but Primer3 is still displayed, field is selected
- Click on Melting temperature label
- "Rough-tm-algorithm" is displayed on the screen. It's correct.
- Again click on "Rough-tm-algorithm"
Unexpectedly "Primer3" is displayed, see attachment.